Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Intervalo de ano de publicação
1.
Clin Oral Investig ; 26(3): 3261-3271, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35006292

RESUMO

OBJECTIVE: To evaluate the physical-chemical (weight, pH, quantification of hydrogen peroxide) and mechanical (texture profile and rheology tests) properties of the experimental bleaching gel based on the bioadhesive polymer Aristoflex® AVC, after accelerated stability testing. MATERIALS AND METHODS: A total of 300 syringes of bleaching gels were divided into 5 groups (n = 60): Whiteness Perfect® 10%-FGM (WP); carbamide peroxide 10% with aristoflex (CPa); carbamide peroxide 10% with Carbopol (CPc); aristoflex thickener (A); and Carbopol thickener (C). According to the following requirements and time, the accelerated stability test was performed: in an incubator at 40 °C and 75% humidity per 1, 3, and 6 months, and baseline (refrigerator at 5 °C and 25% humidity). The variables were analyzed following the statistical tests: Two-way ANOVA and Tukey's test were applied to pH; weight data were analyzed using a mixed model for repeated measurements over time and the Tukey-Kramer test; one-way ANOVA and Tukey's test analyzed the rheology test; generalized linear models were used to quantify the peroxide amount and texture profile data. A significance level of 5% was considered. RESULTS: The experimental bleaches CPa and CPc had the highest pH values when compared to the others in 6 months. Thickeners A and C did not change the pH, weight, and active content over the accelerated stability times (p > 0.05). Furthermore, there was weight loss after 3 months of storage for CPa and CPc (p < 0.05). In the quantification of hydrogen peroxide, the WP group showed the highest values over time (p < 0.0001), only showing a significant loss after the 3rd month. Meanwhile, CPa and CPc showed a reduction in quantification from the 1st month. CONCLUSIONS: Temperature and humidity directly influenced the active content and properties of bleaching gels. In addition, the presence of components regardless of thickeners, such as stabilizers, in the commercial gel allowed for greater stability over time. CLINICAL RELEVANCE: The development of experimental bleaching gels for clinical use requires careful testing. Therefore, accelerated stability testing represents a valuable tool in the development and evaluation of cosmetic formulations.


Assuntos
Clareadores Dentários , Clareamento Dental , Peróxido de Carbamida , Géis , Peróxido de Hidrogênio , Peróxidos , Polímeros , Clareadores Dentários/química , Ureia
2.
Braz. J. Pharm. Sci. (Online) ; 58: e19501, 2022. graf
Artigo em Inglês | LILACS | ID: biblio-1383974

RESUMO

Abstract This study reviews the knowledge on the use of conventional dental whitening and the use of enzymes as a new approach in bleaching. A review of the literature was based on academic articles and on patents related to the use of enzymes in dental bleaching. Tooth whitening techniques used nowadays are well reported in the literature, and its mechanism of action consists of an oxidoreduction reaction with the release of free radicals. The great instability of radicals, when in contact with the tissues, promotes oxidation and reduction in the size of the pigment chains incorporated into them. These pigments are eventually broken down into smaller and smaller molecular chains and end up being diffused from the dental structure. In turn, the use of enzymes aimed at tooth whitening can be a less harmful alternative to the tooth because their specificity regarding the substrate makes them of great interest to perform specific reactions, reducing collateral effects. The use of proteolytic enzymes and oxidoreductases paired with the application of peroxides, can be a promising alternative for obtaining even better results in the dental bleaching process.


Assuntos
Enzimas/análise , Clareadores Dentários/análise , Oxirredutases/administração & dosagem , Dente , Odontologia/classificação , Literatura
3.
J Clin Exp Dent ; 12(2): e116-e122, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32071692

RESUMO

BACKGROUND: Commercial bleaching gels with remineralizing agents were developed to reduce the adverse effects of dental bleaching. The present study evaluated the effects on teeth of in-office bleaching gels containing 35-40% hydrogen peroxide (HP) with Calcium (Ca) or Fluoride (F). MATERIAL AND METHODS: Bovine enamel/dentin blocks (4x4x2.5 mm) were randomly divided into the following groups (n=12): no treatment (control); 35% HP (Whiteness HP, FGM); 35% HP with Ca (Whiteness HP Blue, FGM); 40% HP with F (Opalescence Boost, Ultradent). The specimens were analyzed for color (ΔL*, Δa*, Δb*, and ΔE), roughness (Ra), and Knoop microhardness (KHN). The color and KHN data were submitted to ANOVA and Tukey's test, while Ra values were analyzed using mixed models for repeated measures and Tukey-Kramer's test (α=0.05). RESULTS: The bleached groups did not exhibit statistical differences among them for color. For roughness, 35% HP provided a slight increase of Ra, which was statistically different from the control. For microhardness, 35% HP and 40% HP with F presented KHN values that were statistically lower from the control, while the 35% HP with Ca did not statistically differ from the control. CONCLUSIONS: The presence of Ca or F in bleaching gels did not interfere with bleaching efficacy. However, only the enamel exposed to the bleaching gel containing Ca obtained microhardness values similar to unbleached enamel. Key words:Hydrogen peroxide, tooth bleaching, tooth bleaching agents, laboratory research.

4.
Braz Oral Res ; 33: e037, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31508726

RESUMO

Iontophoresis is a noninvasive technique, based on the application of a constant low-intensity electric current to facilitate the release of a variety of drugs, whether ionized or not, through biological membranes. The objective of this research was to evaluate the effect of iontophoresis using different electric current intensities on the uptake of fluoride in dental enamel with artificial caries lesions. In this in vitro operator-blind experiment, bovine enamel blocks (n = 10/group) with caries-like lesions and predetermined surface hardness were randomized into 6 groups: placebo gel without fluoride applied with a current of 0.8 mA (negative control), 2% NaF gel without application of any current, and 2% NaF gel applied with currents of 0.1, 0.2, 0.4 and 0.8 mA. Cathodic iontophoresis was applied for 4 min. The concentration of loosely bound fluoride (calcium fluoride) and firmly bound fluoride (fluorapatite) was determined. The results were analyzed by the nonparametric Kruskal-Wallis and Dunn tests. Iontophoresis at 0.8 mA, combined with the application of fluoridated gel (2% NaF), increased fluoride uptake in enamel with caries-like lesions, as either calcium fluoride or fluorapatite.


Assuntos
Cariostáticos/farmacologia , Cárie Dentária , Esmalte Dentário/efeitos dos fármacos , Fluoretos/farmacologia , Iontoforese/métodos , Animais , Apatitas/análise , Fluoreto de Cálcio/análise , Bovinos , Modelos Animais de Doenças , Eletricidade , Dureza/efeitos dos fármacos , Distribuição Aleatória , Propriedades de Superfície/efeitos dos fármacos , Resultado do Tratamento
5.
Braz. oral res. (Online) ; 33: e037, 2019. tab, graf
Artigo em Inglês | LILACS | ID: biblio-1001598

RESUMO

Abstract: Iontophoresis is a noninvasive technique, based on the application of a constant low-intensity electric current to facilitate the release of a variety of drugs, whether ionized or not, through biological membranes. The objective of this research was to evaluate the effect of iontophoresis using different electric current intensities on the uptake of fluoride in dental enamel with artificial caries lesions. In this in vitro operator-blind experiment, bovine enamel blocks (n = 10/group) with caries-like lesions and predetermined surface hardness were randomized into 6 groups: placebo gel without fluoride applied with a current of 0.8 mA (negative control), 2% NaF gel without application of any current, and 2% NaF gel applied with currents of 0.1, 0.2, 0.4 and 0.8 mA. Cathodic iontophoresis was applied for 4 min. The concentration of loosely bound fluoride (calcium fluoride) and firmly bound fluoride (fluorapatite) was determined. The results were analyzed by the nonparametric Kruskal-Wallis and Dunn tests. Iontophoresis at 0.8 mA, combined with the application of fluoridated gel (2% NaF), increased fluoride uptake in enamel with caries-like lesions, as either calcium fluoride or fluorapatite.


Assuntos
Animais , Bovinos , Cariostáticos/farmacologia , Iontoforese/métodos , Cárie Dentária , Esmalte Dentário/efeitos dos fármacos , Fluoretos/farmacologia , Apatitas/análise , Propriedades de Superfície/efeitos dos fármacos , Fluoreto de Cálcio/análise , Distribuição Aleatória , Resultado do Tratamento , Modelos Animais de Doenças , Eletricidade , Dureza/efeitos dos fármacos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...